EH Electric Furnace

nl2b.gif (20692 bytes)
• 10 to 30kw Output in 5kw increments or optional 9 to 27kw in 4.5kw increments
• A/C ready
• Hi/Lo continuous fan switch for constant circulation at either a hi or low direct drive speed. (Overridden by heating operation.)
• Direct Drive 240v 1/2 h/p 4 speed motor for lower electrical use
• G10-8 blower assembly for quiet operation
• Nickel-Chrome elements provide extra long life and exceptional heat transfer characteristics
• Multi-Position: down-flow, up-flow, horizontal-left or horizontal-right
• Hi/Econo heat switch increase or decrease in furnace output by either: (see sidebar)
a. Homeowner manual operation
b. 2 stage indoor thermostat*
c. Outdoor temperature switch*
• Certified for zero clearance installation
• Heavy duty 20ga panel construction
• 20” x 20” x 1” replaceable filter and mounting rack supplied
• 24v control circuit
• Time delay sequencer for optimum electric element start up
* Not supplied.

Hi/Econo Heat Switch

• This switch is provided on some models. It is located on the front of the furnace and provides the homeowner with the option of manually increasing or reducing the heating power of the furnace. It can be used to manually switch from "Hi" to "Econo" if less heating power is temporarily desired, depending on the outdoor temperature.

• This switch can also be controlled automatically by a suitable multi- or two-stage thermostat connected to the W1 (Econo) and W2 (Hi) terminals. Set the switch to "Econo" if a two stage or multi-stage thermostat is used.

• If a standard thermostat is connected across W1-R, a remote switch or an outdoor temperature switch can be connected across OT-W2 to switch from "Econo" to "Hi" as the outdoor temperature drops. Leave the furnace switch in "Econo" if a remote or outdoor temperature switch is used.

Clearance to Combustibles

The Newmac EH Electric Furnace may be installed in the up-flow, down-flow, horizontal-left or horizontal-right positions with the following clearances to combustibles:
Sides 0"
Rear 0"
Front (For Servicing) 24"
Warm Air Plenum and Duct 0"


Locate the furnace to provide:
• Best heat distribution
• Shortest supply cable*
• Least interference with present or future plans
* Use 75ºC copper supply sized according to the minimum ampacity. This should be connected to a seperate fused disconnect switch to power the furnace. Suitable ground must be provided. Follow local codes.

EH Specifications 240v

DIRECT DRIVE
BELT DRIVE*
MODEL STATIC PRESSURE DIRECT DRIVE CFM DIRECT VARIABLE SPEED BLOWER BELT CFM BELT APPROX TEMP
INS WC SPEED DRIVE MOTOR PULLEY (TO) PULLEY INS INS DRIVE RISE Fû
DIRECT
EH10*
Lo 900 3-1/4" (0) 6 40 1,400 35
EH15* 0.2 Lo 900 3-1/4" (2) 5 38 1,200 35
0.5 MLo 1,100 3-1/4" (0) 6 40 1,400 45
EH20* 0.2 MLo 1,000 3-1/4" (2) 5 38 1,200 45
0.5 MHi 1,300 3-1/4" (0) 6 40 1,400 50
EH25* 0.2 MHi 1,200 3-1/4" (2) 5 38 1,200 50
0.5 MHi 1,300 3-1/4" (0) 6 40 1,400 60
EH30* 0.2 MHi 1,200 3-1/4" (2) 5 38 1,200 65
0.5 Hi 1,400 3-1/4" (0) 6 40 1,400 65
0.2 Hi 1,300 3-1/4" (2) 5 38 1,200 70
EH9* 0.5
Lo 900 3-1/4" (0) 6 40 1,400 30
EH14* 0.2 Lo 900 3-1/4" (2) 5 38 1,200 30
0.5 MLo 1,100 3-1/4" (0) 6 40 1,400 40
EH18* 0.2 MLo 1,000 3-1/4" (2) 5 38 1,200 40
0.5 MHi 1,300 3-1/4" (0) 6 40 1,400 40
EH23* 0.2 MHi 1,200 3-1/4" (2) 5 38 1,200 45
0.5 MHi 1,300 3-1/4" (0) 6 40 1,400 55
EH27* 0.2 MHi 1,200 3-1/4" (2) 5 38 1,200 60
0.5 Hi 1,400 3-1/4" (0) 6 40 1,400 60
0.2 Hi 1,300 3-1/4" (2) 5 38 1,200 65
0.5


* Notes: 240 volts Direct Drive Standard Model
Special Order Models: a) Belt Drive Blower Assembly, b) 110v motors,
c) High CFM Direct Drive 3 speed 240v 1/2 h/p motor with G10-8 Blower


Specifications

MODEL KW @240v BTU/hr STATIC TEMP RISE DIRECT DRIVE BLOWER MINIMUM MAXIMUM AIR
OUPUT PRESSURE Motor A 240v CIRCUIT CIRCUIT FILTER
EH10D* 10 ins wc 0.20"/0.55" wc 4A 5 spd Ampacity, A Fuse, A ins
EH15D* 15 34,120 0.20/0.50 35/35 4A 5 spd 58 60 1@20X20X1
EH20D* 20 51,180 0.20/0.50 40/40 4A 5 spd 84 90 1@20X20X1
EH25D* 25 68,240 0.20/0.50 45/45 4A 5 spd 110 125 1@20X20X1
EH30D* 30 85,300 0.20/0.50 50/55 4A 5 spd 136 150 1@20X20X1
102,360 0.20/0.50 60/65 162 175 1@20X20X1
MODEL KW @240v BTU/hr STATIC TEMP RISE DIRECT DRIVE BLOWER MINIMUM MAXIMUM AIR
OUPUT PRESSURE Motor A 240v CIRCUIT CIRCUIT FILTER
EH9D* 9 ins wc 0.20"/0.55" wc 4A 5 spd Ampacity, A Fuse, A ins
EH14D* 13.5 30,708 0.20/0.50 30/30 4A 5 spd 52 60 1@20X20X1
EH18D* 18 46,062 0.20/0.50 40/40 4A 5 spd 76 80 1@20X20X1
EH23D* 22.5 61,416 0.20/0.50 40/45 4A 5 spd 99 100 1@20X20X1
EH27D* 27 76,770 0.20/0.50 55/60 4A 5 spd 123 125 1@20X20X1
92,124 0.20/0.50 60/65 146 150 1@20X20X1

FOOTPRINT

Model EH
A Length 22"
B Width 22"
C Height 38" (Belt Drive models 42") DxD Supply Air Plenum 20 1/4" x 20 1/4"
ExE Return Air Plenum* (Not Shown) 18 1/4" x 18 1/4"
Weight 150 lbs.